Technical requirements for pneumatic booster pump
1、 One carbon dioxide booster pump with the following operating conditions:
1. Rated discharge pressure: 30MPa, working temperature: room temperature~80 ℃;
2. Rated flow rate: 10L/h;
3. Medium: The inlet is liquid CO2, and the outlet is liquid or supercritical CO2;
4. Size of inlet and outlet connecting pipes: inlet diameter of 8mm * 1mm, outlet diameter of 8mm * 1mm, connected by card sleeves, length of connecting pipe:>50mm;
5. Carbon dioxide pump head with cooling device (cooling method: pump body air self cooling method);
6. The pump head is double plunger;
7. Manually adjust the flow rate of the pump;
8. Other: Complies with industry standards.
Please provide:
1. The model, price, technical parameters, and construction period of the pneumatic booster pump;
2. Provide the external dimension drawing of the booster pump;
2、 According to the appeal customer's request, the pneumatic booster pump solution provided by Feentor Sales Engineering is as follows
1. The carbon dioxide booster pump model ZTD40-CO2 has a rated flow rate of 12.5/H (liquid flow rate), and the price has been sent to the email. The technical parameters are as follows: delivery time is within one week
2. The size and schematic diagram of the carbon dioxide booster pump are as follows