What are the operating steps and precautions for using an air booster pump?

    1、 Operation steps of air booster pump and precautions for machine use


    1. Add lubricating oil to the oil mist generator of the binary system, using 10 # or 20 # mechanical oil in the south and antifreeze mechanical oil or low pour point hydraulic oil in winter in the north. (Below)




    2. Connect the thread dimensions of the inlet and outlet interfaces on the air booster pump;


    3. Close the low-pressure air source ball valve, connect the air source, and adjust the pressure reducing valve on the coupling to ensure that the air pressure is not greater than 116psi (0.8kgf/cm ²)


    4. When the boosting system is working, replace the corresponding joint according to the thread size of the high-pressure vessel joint, start the air compressor, and adjust the driving pressure of the two joint system. Because the output pressure of this equipment is in a 40:1 relationship with the air compressor, when the air source pressure is set to 5 bar, the output pressure is 200 bar;


    5. After the experiment is completed, turn off the air pressure of the air compressor, adjust the pressure of the binary system to 0psi, and after unloading, disassemble the workpiece and complete the experiment.


    2、 Precautions and maintenance of air booster pump during use


    1. When conducting pressure testing, the operator must pay attention to the pressure rise of the high-pressure gauge and the leakage at the connection. If any problems are found, the pump should be stopped immediately, and the pressure should be relieved and eliminated.


    2. The high-pressure pump only serves to increase the pressure, and starting the pump does not increase the displacement. Therefore, when injecting gas into the inspected container in advance, the pump should be stopped to avoid reactive wear on the sealing components of the booster pump.


    3. There must be lubricating oil inside the oil mist device to lubricate the pneumatic pump. Adjust the oil level to around 10 drops per minute, and add oil to the cup only when there is no air pressure.


    4. The accumulated water in the water separation filter should be drained at any time, and the water in the filter cup should be cleaned regularly. When cleaning, first clean the cup with mineral oil and then dry it with low-pressure air. Avoid using acetone, acetaldehyde, acetate, toluene and other solutions for cleaning. Because these solutions will damage the cup.


    5. The pressure testing medium of this machine must be kept clean. If the pressure testing medium is not clean, it will result in poor sealing of the valves of the machine, which will affect its use.


    3、 Precautions for operating compressed air booster pump


    The core component of this gas boosting system is the pneumatic air booster pump of the pneumatic booster machine, which is independently developed by our company through the introduction of foreign technology. This pump has many characteristics such as high output pressure, easy adjustment, automatic pressure maintenance, and high cost-effectiveness, and has been widely used. By adjusting the regulating valve, the input pressure can be regulated, and the output gas can be continuously adjusted accordingly.

    Air booster pump

    Air booster pump